Features
- High common and differential mode attenuation
- Standard designs up to 100 Amps
- Excellent insertion loss characteristics
up to 1 GHz
- Voltage rating 115-250VAC and 400VDC
up to 400 Hz
- Available to meet MIL-F-15733, MIL-STD-461, and MIL-STD-1399 standards
- Available to meet TEMPEST and FCC requirements
- Rugged Construction to meet MIL Standard Environmental conditions
- Custom designs available
|
|
CE03 Testing
Before Competition using Open & Exposed Circuit Card Assembly
After We Suggested a Multisection Box, Closed Metal Box Assembly
|
Mil-Std 461D Testing
Before System as Received has No Filter
After 461D Passed Allowing Customer to Pass CE Requirement
|
Test Specifications
Test Group |
Order of Test |
Examination or Test |
Test Method (Per MIL-STD-202) |
Post Test Requirements |
| IIA |
1 |
Voltage Drop |
Paragraph 4.6.8 of MIL-F-15733 |
Three percent of rated voltage max. |
| 2 |
Leakage Current |
UL 1283 |
Per applicable specification |
| 3 |
Temperature Rise |
MIL-F-15733 Paragraph 4.6.4 |
25°C max. |
| 4 |
Terminal Strength |
Method 211, Condition A |
No evidence of loosening or rupture after 5 lb. of applied force. Line Cords: 35 Lbs. |
| IIB |
1 |
Shock, Medium Impact |
Method 213, Condition G |
Must pass DWV and Insertion Loss |
| 2 |
Vibration, High Frequency |
Method 204, Condition A |
Monitor for shorts or open |
| 3 |
Thermal Shock |
Method 107, Test Condition A |
Pass 90% DWV IR to be 30% of initial |
| 4 |
Humidity |
Method 107, Condition B, except temperature equals 25°C |
Pass 90% DWV IR to be 30% of initial |
| III |
1 |
Life |
Method 108, Condition D 1.2 x Rated AC voltage at max. operating temp. or 1.4 x DC voltage |
Pass 90% DWV insulation resistance to be 30% of initial. |
|